How to: Reprogram the EFOY After Replacement

MOBILE MOUNTING STRUCTURE - EFOY


OVERVIEW: This procedure goes over how to reprogram a new EFOY after it gets replaced in the field. 

TOOLS NEEDED

  • None

PARTS NEEDED

  • EFOY Controller

SAFETY RULES

Before operating or working with an LVT LiveUnit, consult LiveView’s safety guidelines. Failure to completely understand proper safety procedures when dealing with a Live Unit may result in improper use which increases the likelihood of accidents.  To review LVT’s safety guidelines online or to print, please go here:

LVT Safety Guidelines

REPROGRAM THE EFOY CONTROLLER

  1. Power on the EFOY controller by plugging it in. 
  2. Select language: English.
  3. Select and set the type for connector 1 and 2:
    1. Select Connector 1
    2. Select Cartridge
    3. Select M28
    4. Select Connector 2
    5. Select Cartridge
    6. Select M28
  4. Select and set the battery type:
    1. Hit the back button a few times to make sure you’re back at the main menu
    2. Press and hold the menu and ok buttons together to enter the expert menu.
    3. Set Switch on voltage to 24.4 volts
    4. Set Switch off voltage to 28 volts
    5. Set Switch off current to 3 amps
    6. Set max charge time to 12 hours
  5. Press the back button 2-3 times to return to the main menu.