How to: Reprogram the EFOY After Replacement
MOBILE MOUNTING STRUCTURE - EFOY
OVERVIEW: This procedure goes over how to reprogram a new EFOY after it gets replaced in the field.
TOOLS NEEDED
- None
PARTS NEEDED
- EFOY Controller
SAFETY RULES
Before operating or working with an LVT LiveUnit, consult LiveView’s safety guidelines. Failure to completely understand proper safety procedures when dealing with a Live Unit may result in improper use which increases the likelihood of accidents. To review LVT’s safety guidelines online or to print, please go here:
REPROGRAM THE EFOY CONTROLLER
- Power on the EFOY controller by plugging it in.
- Select language: English.
- Select and set the type for connector 1 and 2:
- Select Connector 1
- Select Cartridge
- Select M28
- Select Connector 2
- Select Cartridge
- Select M28
- Select and set the battery type:
- Hit the back button a few times to make sure you’re back at the main menu
- Press and hold the menu and ok buttons together to enter the expert menu.
- Set Switch on voltage to 24.4 volts
- Set Switch off voltage to 28 volts
- Set Switch off current to 3 amps
- Set max charge time to 12 hours
- Press the back button 2-3 times to return to the main menu.